What are the components of a natural gas generator system?

Release time:2023-04-06 Publisher:ZHONGTUO
1. Gas generator host
The working principle of the gas generator host is the same as that of the gasoline generator. After reliable performance modification and improvement, only the fuel is changed from gasoline to natural gas, utilizing mature and stable internal combustion engine technology. After the generator outputs stable and reliable AC power, the steady-state adjustment rate and fluctuation rate of voltage (frequency), the deviation of line voltage under asymmetric loads, the sine distortion rate of line voltage waveform, the transient voltage (frequency) adjustment rate and stability time all meet the requirements of national standards.
 
2. Automatic control system
 
Equipped with an automatic control system that can monitor the working status of the unit in real-time, truly achieving unmanned operation in the computer room.
 
In addition to cooperating with the combustible gas sensor inside the box, the automated monitoring system can also cooperate with the combustible gas sensor installed indoors to transmit alarms to the automatic control box, cut off the gas pipeline, lock the unit operation, and ensure the overall safety of the computer room; At the same time, the automated monitoring system cooperates with the temperature sensor and oil level sensor inside the box to closely monitor the operation status of the unit; When the temperature exceeds the safety setting value, the unit will be directly stopped, locked, and the gas pipeline will be cut off. It can be managed by the mobile operation and maintenance management center through the RS222 interface, and centrally monitor the operating status of each base station unit, including signals and alarm information such as voltage, current, frequency, temperature, gas, oil level, etc. The center can directly and remotely control the start and stop of the unit as needed.
 
The automatic control system can achieve the following safety protection functions: overvoltage protection, undervoltage protection, overload protection, frequency protection, gas leakage protection, chassis temperature protection, low oil level protection, and cooling water temperature protection.
 
3 Silent damping system
大红鹰93343论坛
 
The silent vibration reduction system includes a silent vibration reduction chassis and an inlet and outlet air silencer. The use of a silent system greatly reduces the mechanical noise of the engine, and in conjunction with the silent vibration reduction chassis and a large air duct silencer, it meets the high demand for silence.
 
When using an enhanced configuration, the minimum noise can reach below 45db, meeting the requirements of various environmental uses.
 
4 Gas system
The gas system mainly consists of gas storage tanks and gas control components. In recent years, mature gas cylinder storage technology has created basic conditions for the promotion of natural gas generators. Currently, the use of gas cylinders should comply with national safety standards.
 
5. Usage Model of Natural Gas Generators
The natural gas generator is installed in a fixed manner in the communication base station, and the generator outputs AC power and is connected to the existing base station AC input distribution box. In the event of a power outage in the city, priority should be given to battery power supply. When the battery is discharged to a certain extent (through voltage detection), the natural gas power generation equipment will automatically start to generate electricity. After starting, the generator can carry all the electrical equipment in the base station.
 
The automatic control system of the natural gas generator itself has an RS222 intelligent output interface, which can be directly connected to a mature monitoring network. The monitoring center can read various operating data and status of natural gas generators, such as voltage, current, frequency, temperature, gas, oil level, and other signals and alarm information.
 
Natural gas generators are fixed installed in base stations and can be considered for the following applications:
 
a. Portable diesel generator cannot enter the area for power generation.
 
b. It is sensitive to the noise of portable diesel generator.
 
c. A base station located far from the power generation support center.
 
Thank you for reading. The exciting content of this article comes from: Analyzing Gas Generator Units. We will continue to present more exciting content for you. For more details, please click:

Service

classification

product

recommendation

Contact

Information
  • Tel:0531-69953988
    13012995645
  • Add:101, Building 5, Liandong U Valley Science and Technology Innovation Center, Zhangjin Comprehensive Bonded Zone, No. 33688 Jingshi East Road, Suncun Street, Jinan Area, China (Shandong) Pilot Free Trade Zone

截屏,微信识别二维码